oil boiler with capacity 500000 kcal h
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
6. A water tube boiler has a capacity of 1000 kg/hr of steam. The factor of evaporation is 1.3, boiler rating is 200%, boiler efficiency is 65%, heating surface area is 0.91 m 2 per Bo. Hp, and the heating value of fuel is 18,400 kCal/kg. The total coal available in the bunker is 50,000 kg. Determine the no. of hours to consume the available fuel.Get Price
Some forms of silica, known as colloidal, or non-reactive, are not removed by a demineralizer. Hot, alkaline boiler water dissolves the colloidal material, forming simple silicates that are similar to those that enter the boiler in a soluble form. As such, they can form deposits on tube surfaces and volatilize into the steam. DEALKALIZATIONGet Price
Jan 05, 2012 · Calorific value is basically a measurement of energy or heat released (kJ or kcal) when 1 After heat recovery in a boiler, the de-dusted, The first plant, at Hoyt Lakes, MN, began operating in 2010 and it had an annual capacity of 500,000 Get Price
Jan 05, 2012 · Calorific value is basically a measurement of energy or heat released (kJ or kcal) when 1 After heat recovery in a boiler, the de-dusted, The first plant, at Hoyt Lakes, MN, began operating in 2010 and it had an annual capacity of 500,000 Get Price
6. A water tube boiler has a capacity of 1000 kg/hr of steam. The factor of evaporation is 1.3, boiler rating is 200%, boiler efficiency is 65%, heating surface area is 0.91 m 2 per Bo. Hp, and the heating value of fuel is 18,400 kCal/kg. The total coal available in the bunker is 50,000 kg. Determine the no. of hours to consume the available fuel.Get Price
Jan 05, 2012 · Calorific value is basically a measurement of energy or heat released (kJ or kcal) when 1 After heat recovery in a boiler, the de-dusted, The first plant, at Hoyt Lakes, MN, began operating in 2010 and it had an annual capacity of 500,000 Get Price
6. A water tube boiler has a capacity of 1000 kg/hr of steam. The factor of evaporation is 1.3, boiler rating is 200%, boiler efficiency is 65%, heating surface area is 0.91 m 2 per Bo. Hp, and the heating value of fuel is 18,400 kCal/kg. The total coal available in the bunker is 50,000 kg. Determine the no. of hours to consume the available fuel.Get Price