1000 kg hr steam boiler to kw

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :1000 kg hr steam boiler to kw
  • Supply Capacity : 10 units/month :1000 kg hr steam boiler to kw
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

Get display discount

Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • Agricultural Anaerobic Digesters: Design and Operation

    Dec 01, 2016 · The manufacturer's rating for boilers indicated a boiler efficiency of 0. 7 with LP gas and 0.78 with natural gas. The value of 0.58 was used in calculating the needed boiler capacity due to intermittent and low-load operation. A boiler with a rated input value of 66,000 Btu/hr (19.5 kW) was selected for the Penn State digester installation.Get Price

  • MCQ in Power Plant Engineering Part 8 | ME Board Exam

    Dec 19, 2020 · 379. A water tube boiler has a capacity of 1000 kg/hr of steam. The factor of evaporation is 1.3, A 6 MW steam turbine generator power plant has a full-load steam rate of 8 kg/kW-hr. Assuming that no-load steam consumption as 15% of full-load steam consumption, compute for the hourly steam consumption at 75% load, in kg/hr.Get Price

  • Watt Calculator - Joules - Watts - Kilowatts - Therms

    Power-Units Conversion 1kW (KiloWatt) = 3414 BTU/hr . 0.746kW= 1hp . Power rating of steam-boliers is in units of BHP (boiler -horsepower) One BHP (Boiler Power)= 33,500 BTU/hr = 9.803 kilowatts (The Boiler-BHP power unit is a bit confusing becasue BHP could be confused with brake-horsepower (bhp) which is an auto-industry terminology)Get Price

  • Steam Generators and Fluid Heaters Clayton Industries

    Clayton is an industrial steam boiler manufacturer of fired steam generators and fluid heater steam generators. Clayton's industrial process steam boilers are available in 18 sizes from 15 to 2000 Boiler Horsepower (150 to 20,000 kW) and 518 to …Get Price

  • Boiler Capacity - Engineering ToolBox

    Example - Boiler Horsepower to lbs of Steam Conversion. 200 hp x 34.5 = 6900 lbs of steam per hour. Lbs of steam can be converted to hp by dividing lbs steam per hour by 34.5. Example - Lbs of Steam to Boiler Horsepower Conversion. 5000 lbs of steam / 34.5 = 145 hp boiler. Converting Boiler Horse Power (BHP) to kBtu/hrGet Price

  • MCQ in Power Plant Engineering Part 8 | ME Board Exam

    Dec 19, 2020 · 379. A water tube boiler has a capacity of 1000 kg/hr of steam. The factor of evaporation is 1.3, A 6 MW steam turbine generator power plant has a full-load steam rate of 8 kg/kW-hr. Assuming that no-load steam consumption as 15% of full-load steam consumption, compute for the hourly steam consumption at 75% load, in kg/hr.Get Price

  • Steam Generators and Fluid Heaters Clayton Industries

    Clayton is an industrial steam boiler manufacturer of fired steam generators and fluid heater steam generators. Clayton's industrial process steam boilers are available in 18 sizes from 15 to 2000 Boiler Horsepower (150 to 20,000 kW) and 518 to …Get Price

  • Complete Combustion - an overview | ScienceDirect Topics

    Notice that for each kg of fuel entering combustion, there is 16.7 kg of air required as a minimum! In reality, more air than this must be supplied, since some excess air is required to insure complete combustion.For natural gas, an efficient boiler would use about 15 percent excess air, or roughly 19 kg per kg of fuel.Get Price

  • (PPT) PIPE 1 COACHING NOTES 150 | pauline agustin

    A. 124.78 kW B. 135.81 kW C. 167.25 kW D. 225.78 kW 69. 23.5 kg of steam per second at 5 Mpa and 400oC is produced by a steam generator. The feed water enters the economizer at 145oC and leaves at 205oC. The steam leaves the boiler drum with a quality of 98%.Get Price

  • Boiler Efficiency - an overview | ScienceDirect Topics

    P. GoldsWorthy, E. On, in The Coal Handbook: Towards Cleaner Production: Coal Utilisation, 2013. Boiler efficiency and carbon burnout. Boiler efficiency is a measure of how effectively chemical energy in fuel is converted into heat energy in steam going to the turbines. The largest boiler efficiency loss is sensible heat lost as hot flue gases (and ash) exit the boiler.Get Price

  • Compre Special Project (PPE &IPE) | PDF | Boiler | Thermal

    Steam at the rate of 70,000 kg/hr from the boiler drum enters the superheater inlet header at 8.3 Mpa and 485oC. Combustion products at 980oC enters the superheater proper at the rate of 160,000kg/hr. Superheater elements are made of 60 mm O.D. by 8 …Get Price

  • Compre Special Project (PPE &IPE) | PDF | Boiler | Thermal

    Steam at the rate of 70,000 kg/hr from the boiler drum enters the superheater inlet header at 8.3 Mpa and 485oC. Combustion products at 980oC enters the superheater proper at the rate of 160,000kg/hr. Superheater elements are made of 60 mm O.D. by 8 …Get Price

  • Byworth Boilers | Industrial Steam Boilers and Industrial

    Byworth Boiler Hire is the UK's leading industrial boiler hire company for both steam and hot water systems. Our portable steam boiler hire range is available from 450 – 7,000 kg/hr for single boiler installations and our hot water boilers range from 250 – 3000 kW/hr.Get Price

  • Croydon power stations - Wikipedia

    The steam capacity of the boilers was 2,560,000 lb/hr (322.6 kg/s). Steam conditions at the turbine stop valve were 600 psi (41.4 bar) and 454 °C. In 1963-64 the overall thermal efficiency of the B station was 24.58 per cent. Electricity output from Croydon B power station during its final years of operation was as follows.Get Price

  • Power plant and calculations: Boiler calculations for

    Feb 12, 2021 · Heat loss in terms of fuel = Heat loss / (Fuel GCV X Boiler efficiency) = 17500 / (4500 X 0.9) =4.32 kg/hr. So extra coal consumption to compensate the heat loss = 4.32 X 24 =103.7 kg/day. 33-A boiler of generates 85 TPH of steam at pressure 65 kg/cm2 & temperature 490 deg C, calculate the velocity of this steam if it passes through 150 NB Get Price

  • Biomass Gasification 101

    – 20 kg/hr to 300 tonnes/day – Air-blown – Atmospheric pressure – 500-1,000ºC – Fixed bed or fluid bed – Syngas is combusted directly in a boiler to make steam for a steam turbine generatorGet Price

  • Economizer - Wikipedia

    The first successful economizer design was used to increase the steam-raising efficiency of the boilers of stationary steam engines.It was patented by Edward Green in 1845, and since then has been known as Green's economiser.It consisted of an array of vertical cast iron tubes connected to a tank of water above and below, between which the boiler's exhaust gases passed.Get Price

  • 2. One-Dimensional Steady-State Conduction – Heat Transfer

    Oct 14, 2021 · (Ans. 1090 kW/m 2, 1102 K) Find the rate of heat flow through 1 m 2 of the heating surface of the boiler if the flue gas temperature is 1273 K. The boiling water temperature is 473 K. The coefficient of heat transfer 2 from the flue gases to the walls is 0.1kW/m 2 and that from the walls to the water is 5 kW/m. The thermal conductivity of the Get Price

  • Byworth Boilers | Industrial Steam Boilers and Industrial

    Byworth Boiler Hire is the UK's leading industrial boiler hire company for both steam and hot water systems. Our portable steam boiler hire range is available from 450 – 7,000 kg/hr for single boiler installations and our hot water boilers range from 250 – 3000 kW/hr.Get Price

  • Tabel Konversi Satuan | Andarkusuma's Blog

    Jan 05, 2013 · 1 horsepower (electric) = 2547.16 Btu/hr (thermo) = 2545.46 Btu (IST)/hr = 2543.49 Btu (mean)/hr = 178.298 calorie/sec (thermo) = 641.87 calorie, kg/hr (thermo) = 7.46×10 9 erg/sec = 33013 foot pound-force/min = 550.2 foot pound-force/sec = 1.0004 horsepower (mech) = 0.07605 horsepower (boiler) = 1.01428 horsepower (metric) = 0.99994 Get Price

  • Complete Combustion - an overview | ScienceDirect Topics

    Notice that for each kg of fuel entering combustion, there is 16.7 kg of air required as a minimum! In reality, more air than this must be supplied, since some excess air is required to insure complete combustion.For natural gas, an efficient boiler would use about 15 percent excess air, or roughly 19 kg per kg of fuel.Get Price

  • Tabel Konversi Satuan | Andarkusuma's Blog

    Jan 05, 2013 · 1 horsepower (electric) = 2547.16 Btu/hr (thermo) = 2545.46 Btu (IST)/hr = 2543.49 Btu (mean)/hr = 178.298 calorie/sec (thermo) = 641.87 calorie, kg/hr (thermo) = 7.46×10 9 erg/sec = 33013 foot pound-force/min = 550.2 foot pound-force/sec = 1.0004 horsepower (mech) = 0.07605 horsepower (boiler) = 1.01428 horsepower (metric) = 0.99994 Get Price

  • Boiler Efficiency - an overview | ScienceDirect Topics

    P. GoldsWorthy, E. On, in The Coal Handbook: Towards Cleaner Production: Coal Utilisation, 2013. Boiler efficiency and carbon burnout. Boiler efficiency is a measure of how effectively chemical energy in fuel is converted into heat energy in steam going to the turbines. The largest boiler efficiency loss is sensible heat lost as hot flue gases (and ash) exit the boiler.Get Price

  • Boiler Capacity - Engineering ToolBox

    Example - Boiler Horsepower to lbs of Steam Conversion. 200 hp x 34.5 = 6900 lbs of steam per hour. Lbs of steam can be converted to hp by dividing lbs steam per hour by 34.5. Example - Lbs of Steam to Boiler Horsepower Conversion. 5000 lbs of steam / 34.5 = 145 hp boiler. Converting Boiler Horse Power (BHP) to kBtu/hrGet Price

  • Tomato Processing Plant - Sauce, Ketchup, Paste - Tomato

    Capacity 1000 to 10000 Kg/Hr. Min 5000 Kg /Hr Max 30.000 Kg/Hr. Machine Power: 0-40 kw: Power Consumption: Depend Capacity: Capacity: Steam Boiler with Water softener, Cooling Tower, pump piping, Air compressor, Effluent Treatment Plant, Boiler Chimney, All …Get Price

  • (PPT) PIPE 1 COACHING NOTES 150 | pauline agustin

    A. 124.78 kW B. 135.81 kW C. 167.25 kW D. 225.78 kW 69. 23.5 kg of steam per second at 5 Mpa and 400oC is produced by a steam generator. The feed water enters the economizer at 145oC and leaves at 205oC. The steam leaves the boiler drum with a quality of 98%.Get Price

  • Direct and Indirect efficiency in boilers

    Direct method is quick method for boiler efficiency calculation, In this method, Percentage of total heat output vs heat input is calculated to establish boiler performance. Boiler Efficiency = Heat output / Heat Input X 100. Or Boiler Efficiency = Q X (h2 – h1) / (q X GCV) X 100. Where Q = Qty of steam generated.Get Price

  • Power plant and calculations: Boiler calculations for

    Feb 12, 2021 · Heat loss in terms of fuel = Heat loss / (Fuel GCV X Boiler efficiency) = 17500 / (4500 X 0.9) =4.32 kg/hr. So extra coal consumption to compensate the heat loss = 4.32 X 24 =103.7 kg/day. 33-A boiler of generates 85 TPH of steam at pressure 65 kg/cm2 & temperature 490 deg C, calculate the velocity of this steam if it passes through 150 NB Get Price